Showroom open today until 5pm Unit 2, Lockyard Lane, Banbury · 01632 960 418
Tredwell & DaughterCarpets and flooring, Banbury Book a free measure

Home / Journal

Underfloor heating and choosing a floor

27 October 2026 · 5 minute read · Hannah Tredwell

More of the homes we measure have underfloor heating than ever before. Nearly every new house on the edge of Banbury has it downstairs, and a lot of extensions and kitchen refits add it. The good news is that almost every floor we fit can go over it. The detail is in choosing the right version of each floor and looking after it properly in the first few weeks.

How underfloor heating changes things

There are two main kinds of system:

  • Wet systems run warm water through pipes, usually set into a screed, from a boiler or heat pump. These are most common in new houses and extensions.
  • Electric systems use thin heating mats or cables, often laid on top of an existing floor under the new floor covering. These are common in bathrooms and single rooms.

Either way, the floor covering sits between the heat and the room. Anything that acts as insulation slows down how quickly heat gets through, which can make the system less efficient and slower to respond. And the floor itself has to cope with being warmed and cooled, sometimes every day.

The 27°C limit

For most hard floors, manufacturers set a maximum floor surface temperature, and the most common figure is 27°C. That is the temperature of the surface you walk on, not the temperature of the water in the pipes, which is usually much higher. Some products set a lower limit, so we always check the instructions for the range you choose.

The best way to make sure the limit isn't exceeded is a floor temperature probe connected to the controls, which cuts off the heating if the floor gets too warm. If your heating installer can fit one, it is worth asking.

Floor by floor

LVT. Very suitable. It is thin, so heat passes through it quickly. Glue-down LVT is our first choice over underfloor heating, because being stuck down means it doesn't move as the floor warms and cools. Most ranges set the 27°C surface limit. Click LVT can also be used with a suitable underlay, but check the product.

Sheet vinyl. Suitable, usually with the same 27°C limit. Check the specific range.

Engineered wood. Suitable, and much better than solid wood. The layered core makes it stable enough to cope with the heating. Gluing it down gives the best heat transfer, and thinner boards let heat through more readily than thick ones. Expect small gaps between boards to appear in winter when the heating has been on for a while. They close again in the warmer months.

Solid wood. We generally don't recommend it over underfloor heating. Solid boards move much more with changes in temperature and moisture, and they are more likely to cup or gap badly. There are a few narrow solid boards approved for it, but engineered wood is the safer choice.

Laminate. Many laminates are approved for underfloor heating with a suitable underlay. Check the manufacturer's instructions for the product.

Carpet. Carpet can go over underfloor heating, but the carpet and underlay together act as insulation. The measure for this is the tog rating, the same idea as on a duvet. The usual guidance is that carpet and underlay together should be under 2.5 tog. If your heating runs from a heat pump, which works at lower water temperatures, the advice is to keep it under 1.5 tog. Underlays made for underfloor heating are usually around 0.5 to 0.6 tog, which leaves room for the carpet. Thinner, denser carpets have lower tog ratings. Very thick, heavy wool carpets can be over the limit on their own. We'll check the combined figure for the carpet and underlay you are choosing, and if you're unsure what your system can cope with, it is worth asking your heating installer.

Before we fit

The heating needs to have been run before the floor goes down, particularly in a new screed. A new screed has to dry out before any floor is laid on it, and running the heating is part of drying it. Your heating installer should have a commissioning procedure for this. We'll still test the screed for moisture before laying a hard floor.

When we confirm your fitting date, we'll tell you what to do with the heating beforehand. For most hard floors, it means turning the heating down or off for a day or two before fitting, so that the floor is at a normal room temperature when we lay it.

Wood needs to acclimatise in the room before it is fitted. We deliver it a few days early and ask you to leave the boxes flat and unopened in the room.

After we fit

This is where problems usually start, so please follow the instructions we leave.

For most hard floors, keep the heating off or very low for at least 48 hours after fitting, especially if the floor is glued down, so the adhesive can cure. Then bring the temperature up gradually, a couple of degrees a day, rather than turning it straight up to full. Wood in particular reacts badly to sudden changes. Manufacturers' instructions vary, and some ask for longer, so follow the sheet for your floor.

Do the same in reverse at the end of the heating season, and avoid big daily swings in temperature where you can. Rugs and large items of furniture sitting flat on the floor can trap heat underneath them, so avoid thick rugs on underfloor heating and use furniture with legs where possible.

Electric mats in bathrooms

If you're having an electric mat put into a bathroom, it is usually laid on a prepared floor and covered with a levelling compound before the floor covering goes on. If we're fitting the floor, it helps to talk to your electrician before the mat goes down, so the levelling is done in a way that suits glue-down LVT or vinyl.

The short version

Glue-down LVT and engineered wood are the most reliable hard floors over underfloor heating. Carpet works if the combined tog rating is low enough. Avoid solid wood. Keep the floor surface no warmer than 27°C, and bring the heating up slowly after fitting. If you'd like to talk about your system, bring the details along to the showroom or have them to hand when we come to measure.